Incite Fire Catalogue
www.incitefire.com.au for technical information 65 EXPANSION MODULES / SMOKE SENSORS / PVC FITTINGS Smoke Sensors Expansion Modules PVC Fittings SEC-ASD-535 Verschl The fastener plate is for closing the 2nd channel when it is temporarily not used. (e.g. Conversion of a room) The packaging unit of the fastener plate is 50 pieces. Fastener plate to cover a smoke sensor chamber SEC-SSD-535-3 Alarm Sensitivity range 0.02 – 10% /m The smoke sensor SSD 535 has to be ordered separately for the SEC-ASD-535. Pre-signals can be set between 10 and 90% of the alarm threshold. Smoke Sensor for SEC-ASD-535 SEC-SSD-535-3 Alarm Sensitivity range 0.02 – 10% /m The smoke sensor SSD 532 has to be ordered separately for the SEC-ASD-532. 3 Pre-signals can be set between 10 and 90% of the alarm threshold. Smoke Sensor for SEC-ASD-532 SEC-SSD-31 Alarm Sensitivity range 0.02 – 10% /m The smoke sensor SSD 31 is pre-installed in the SEC-ASD-531 and is also available also as replacement part. 3 Pre-signals are set on a fixed percentage of the alarm threshold (30/50/70%). Smoke Sensor for SEC-ASD-531 SEC-DF-25-PVC Flange for tube TU 25 PVC for the monitoring of ventilation ducts. Per duct 3 pieces of DF 25 PVC are required, 2 for the aspirating stub, 1 for the air recirculation. Ventilation duct flange SEC-CC-25-PVC Compressed-air connection for tube TU 25 PVC for cleaning the aspirating tube. Compressed-air connection SEC-SMM-535 This interface connects the RS485 (over SIM 35) networked SEC-ASDs to a USB port of a PC. It is powered by the USB port. Serial Master Module for networking Serial I/F Module networking for SEC-ASD-532 and SEC-ASD-535 SEC-SIM-35 For the RS 485 networking of up to 250 Special Fire Detectors like SEC-ASD-535 or SEC-ASD-532. Using the “ASD Config” configuration software, all SEC-ASDs in the network can be visualised and configured from a PC. The module comes with mounting brackets, screws and ribbon cables. SD-Card Industrial 2GB SEC-SD-Industrial SD memory card (industrial) 2GB to use with MCM 35 or directly on-board in SEC-ASD-531 (AMB 31) and SEC-ASD-532 (AMB 32). Memory card module for SEC-ASD-535 SEC-MCM-35 This Memory Card Module lets you trace up to 16 Million events and stores analogue values like smoke concentration and airflow of at least 83 days depending on the log interval. The module comes with mounting brackets, screws and ribbon cables and SD-Industrial memory card. SEC-RIM-35 The RIM 35 brings five (5) additional relay outputs to your SEC-ASD-535. Expansion limit is two (2) RIM 35 / 10 relays. Each relay can be assigned to any ASD event by programming with the ASD Config software. The module comes with mounting brackets, screws and ribbon cable. Relay I/F module for SEC-ASD-535 SEC-RIM-36 The RIM 36 brings five (5) additional relay outputs to your Special Fire Detector (except SEC-ASD-535). Expansion limit is two (2) RIM 35 / 10 relays. Each relay can be assigned to any ASD event by programming with the SEC-ASD Config software. The module comes with mounting brackets, screws and ribbon cable. Relay I/F module for SEC-ASD-531 and SEC-ASD-532 5 relays with changeover contacts
Made with FlippingBook
RkJQdWJsaXNoZXIy OTk5NjE4